Network PA System for tool to large-scale tasks



Introduction


The XC-9000 system is a totally electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system ensures the right and efficient transmission of all data packets. Not only can it use existing computer system networks, such as LANs or the Web, to send program signals, yet also it can likewise be released on a specialized broadcasting network.


A single-server system can support up to 3000 terminals and allows for server cascading. There are no limitations on the concurrent program channels, achieving real complete electronic broadcasting.


System Characteristics



Adaptable PA System Layout


The PA system architecture is easy, consisting of solution administration software, network microphones, network amplifiers, network speakers, and various other devices.All devices is linked through the TCP/IP intranet protocol, allowing for flexible configuration and very easy administration of the system, with complimentary control over program web content, network gadgets, and regions via the network.


Ip Paging SystemIp Paging System
Comprehensive Audio Management


The audio monitoring software program includes built-in attributes for developing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour shows, enabling altering settings during all day


Versatile Audio Source Assistance


The system supports numerous forms of audio resources for sending out alerts like online speech and BGM playback. Audio resources can come from electronic musical applications, CD/DVD gamers, microphones, etc. Furthermore, the system provides diverse features of supporting various broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Integration


The system has an emergency alarm function and can be integrated right into a smoke alarm system. When the alarm system central system gets the disconcerting signals, the wire will transmit the signal to tools, which sets off the XC-9000, sending signals to audio speakers


Individuals could pick to preset settings to turn on full-area or zoned alarms in emergency situations. The alarm system voices can be found in multiple types and might be modified catering to requirements. For instance, customers can transform language setups, upload and edit their audio sources according to precise needs, such as intruding alarms, fire alarm systems or air help alarm systems, and so on





Fire Alarm System Combination


The system has an emergency alarm feature and can be integrated right into a fire alarm system. When the alarm central system gets the worrying signals, the cable will certainly transmit the signal to tools, which sets off the XC-9000, sending out signals to audio speakers


Users could pick to predetermined settings to activate full-area or zoned alarms in emergencies. The alarm voices been available in numerous kinds and can be modified dealing with requirements. Users can change language settings, upload and edit their audio resources according to specific demands, such as intruding alarm systems, fire alarms or air help alarm systems, and so on.


Application Control for System Procedures


The system allows mobile app login and usage, allowing customers to launch programs and various other operations to accredited terminals through the web server software application, guaranteeing a hassle-free and streamlined experience.


Integrated SIP Compatibility


The system not just allows SIP phones to log in, yet additionally can be linked to third-party SIP server or IPPBX, which establishes a totally integrated and suitable interaction system with seamless combination into existing systems.


Open up SDK


When huge job like wise park happens, the system supplies an open SDK integrated right into third-party application systems - IP Speaker


System Facilities



Key Functions


Scheduled Playback


The system has the ability to immediately relay according to the scheduled jobs as long as individuals upload the audio data for each amount of time of the day to the web server and develop a playback schedule.


Area Broadcasting


The system can randomly divide a few network tools into different zones to play specified audio programs or send statements to any marked location. The quantity of each device can be from another location adjusted.


Real-time Broadcasting


The system can transmit and record radio programs or other exterior audio resources in real-time, and at the exact same time relayed them in sync.


Smoke Alarm Assimilation


The system can be integrated with the emergency alarm system for control. When a fire alarm signal is caused, it automatically turns on the emergency broadcast feature and supports nearby flooring alarm systems. It additionally permits manual emergency broadcasting by clicking a solitary switch.


SIP Phone Combination


The system can be incorporated with SIP web servers, permitting live speech of voice broadcasting using SIP phones to send out announcements anytime and anywhere.


CCTV Assimilation


The electronic devices such as IP POE Speakers embraces the global common ONVIF method, which enables their voices to be transmitted using VMS systems. The terminals can also be incorporated with CCTV systems for integrated program.


Main Products



Audio Administration Software Program XC-9000


B/S design, supports cross-platform applications.
Covers traditional broadcasting system functions, enabling dividers administration.
Unified monitoring of terminals within the system, watching job standing, and batch quantity change, and so on.
Sustains structure multi-level server architectures, try this deploying management according to user geographical regions.
Provides SDK advancement bundles for additional advancement and combination with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Action: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Running Temperature level: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Communication Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Frequency Response: 45Hz~ 18KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Action: 50Hz~ 20KHz.
Operating Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Measurements: 440x300x44mm.


Area Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONING 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux that site Input 01/02: 60Hz~ 16kHz.
Running Temperature level :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP User Interface Unit NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Method: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outcomes.
Running Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Option For School





Adaptable Zoning Broadcast:


The totally network terminals can realize versatile zoning alternatives, permitting relaying notices to specific terminals or different areas ( devices).


School Bell System:


It offers school bell system at the beginning/ending of the class - IP Speaker. Multiple situations can be designed, including different arranged broadcast jobs according to summer/winter timetable


Emergency Alarm Integration


It sustains assimilation with smoke alarm systems, permitting emergency alarm signals to be integrated right into the PA system.


Class Sound Amplification


Terminals support everyday applications in class scenes. They can be connected to projectors or interactive whiteboard for audio boosting.


Ip Pa SystemIp Speaker

Smart Street Lamp/Security Post



Support SIP Protocol:


Integrated SIP procedure for smooth integration with original site network interaction systems.


VMS Operatings Systems Integration:


Integrated ONVIF procedure for assimilation with VMS platforms.


Third-Party Integration:


Integrated In HTTP API for integration with 3rd party platforms.


Voice Alarm System Triggering:


Constructed in alarm system input user interface for setting off voice alarm systems with video cameras.


Option For Resort



Zone Control by Floor:


The system uses complete network settings, dividing areas depending on various floors and control over each area separately.


Smoke Alarm Assimilation:


The system can be integrated with smoke alarm system, allowing assimilation of smoke alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable arranged broadcasting, enabling versatile plans according to different requirements.


Emergency Broadcasting:


It supports emergency broadcasting for the whole area, making it possible for one-click emergency interaction.


Remedy For Factory



Area Broadcasting:


It allows broadcasting to any type of zone, assuring no disturbance between different areas.


Alarm Triggering:


Terminals have different kinds of interfaces, allowing to trigger alarm systems when gotten in touch with electronic cameras.


All Network Devices:


Deployment of completely network gadgets dramatically reduces the difficulty of operating such as examining gadgets on dangerous sites, and thus safeguarding individuals and home.


The deployment of all network devices considerably minimizes the trouble of procedure and upkeep administration


Integrated SIP Phones:


The system can be incorporated with SIP phone and program notices making use of SIP phones any time and anywhere. Two-way sound talkback between SIP phones and IP POE Speakers makes it simple for inspecting tools sitting in workplace or other work environments.


The XC-9000 system is a fully digital network PA system based on the TCP/IP method. By leveraging the TCP/IP protocol, the system ensures the effective and proper transmission of all information packages. The system supports different types of audio resources for sending alerts like live speech and BGM playback. In enhancement, the system gives diverse features of supporting different broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be integrated with the fire alarm system for control.